Electrocardiograph

[:id]

Spesifikasi :
Recording ECG Leads:12 standard leads: I,II,III, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6
Lead Group:Standard / Cabrera / User Defined Combination
Recording Mode:Auto / Manual / Copy / Elapsed / Rhythm / Calibration
Recording Channel:12 / 6 + 1 / 3 + 1 ch
1-ch (lead II) / 2-ch (lead II,V5) / 3-ch (lead I, II, V5) rhytm record
Displaying Channel:12 / 6 / 4 / 3 / 2 / 1 ch
Sensitivity (mm/mV):2.5, 5, 10, 20, [40, Auto (optional)]
Type:Interpretation + Stress ECG Interface
Recording Speed (mm/sec):Auto 5, 10, 12.5, 25, 50, [100 (optional)]
Manual 25, 50
Recording Sytem:High Resolution thermal head printer 8 dots/mm
Resolution : Vertical / Horizontal : 203 / 508 dpi
Recording Paper:216 mm x 30 m thermal sensitivity roll type
A4 or Letter thermal sensitivity z-folder type (option)
Recording Length (Auto):User selected length (5 ~ 25 sec)
ECG Data Acquisition:Simultaneous 12 – lead ECG
Elapsed Rhythm Record:Latest 5 ~ 10 sec signal record
Full Disclosure Report:User selected a lead signal and record compact rhythm for 1 min
Patient Data Input:Alphanumeric key with touch screen key pad
Language:English, Spanish, Russian, Turkish
Frequency Response:Unfiltered 0,05 – 200 Hz (-3dB)
Digital filter:Baseline drift (0,05 / 0.5 Hz)
Muscle (25 / 35 Hz) and AC (50 / 60 Hz)
High frequency noise filter (75 / 100 / 150 / 200 Hz)
Calibration Test (1 mV):Frequency response and sensitivity test using internal 1 mV signal
Auto Power Switch off:After 5, 10, 15 minutes inactive operation
Power Requirements:AC : AC 100 – 240V + 10% ~ 50 / 60 Hz (Fully charged 2 hrs record)
DC : Built – in rechargeable battery (NiMH, + 19,2V, 2200mAh)
A/D conversion:12 bits
Sampling rate:500 Hz (Input Unit : 8,000 Samples/s)
Input impedance:Greater than 100 MΏ
CMRR:Greater than 100 dB
Detection Parameter:Pace Maker Detection (Option) / Variable R-R Detection / Real Timeheart rate
Alarm:Paper empty / Lead-off/ Low Battery Level
Performance:AAMI Requirements
Safety:Class I (Degree of protection againts electric shock
Defibrilation – proof type CF aplied parts
IEC60601-1/IEC60601-2-25
Patient Leakage Current:Less than 10 µA
Digital interference Port:2 USB-RS232, Ethernet LAN, Wireless – Bluetooth (Option)
PC Connection:PC Data Management, PC Net S/W (Option)
Stress ECG Interface, Stress ECG S/W (Option)
External Printer:USB Connection (Inkjet / Laser Printer)
Memory:Internal SD Card to save up to 2500 patient data (10 sec data)
External USB memory stick
Display LCD:7″ Color, 800 x 480dots, Viewing area : 152. 40mm x 91.44 mm
Key Operation:Alphanumeric membrane hard key and touch screen
Dimension:332 x 308 x 103.8 mm
Weight:3.3 Kg Including battery
Temperature:Operating (10 – 40 °C) Storage (-20 – 60 °C)
Relative Humidity:Operating (10 – 80 %) Storage (-0 – 90 %)
Atmosphere pressure:50 – 106 kPa

[:en]

Spesifications :  
Recording ECG Leads:12 standard leads: I,II,III, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6
Lead Group:Standard / Cabrera / User Defined Combination
Recording Mode:Auto / Manual / Copy / Elapsed / Rhythm / Calibration
Recording Channel:12 / 6 + 1 / 3 + 1 ch
   1-ch (lead II) / 2-ch (lead II,V5) / 3-ch (lead I, II, V5) rhytm record
Displaying Channel:12 / 6 / 4 / 3 / 2 / 1 ch
Sensitivity (mm/mV):2.5, 5, 10, 20, [40, Auto (optional)]
Type:Interpretation + Stress ECG Interface
Recording Speed (mm/sec):Auto 5, 10, 12.5, 25, 50, [100 (optional)]
   Manual 25, 50
Recording Sytem:High Resolution thermal head printer 8 dots/mm
   Resolution : Vertical / Horizontal : 203 / 508 dpi
Recording Paper:216 mm x 30 m thermal sensitivity roll type
A4 or Letter thermal sensitivity z-folder type (option)
Recording Length (Auto):User selected length (5 ~ 25 sec)
ECG Data Acquisition:Simultaneous 12 – lead ECG
Elapsed Rhythm Record:Latest 5 ~ 10 sec signal record
Full Disclosure Report:User selected a lead signal and record compact rhythm for 1 min
Patient Data Input:Alphanumeric key with touch screen key pad
Language:English, Spanish, Russian, Turkish
Frequency Response:Unfiltered 0,05 – 200 Hz (-3dB)
Digital filter:Baseline drift (0,05 / 0.5 Hz)
   Muscle (25 / 35 Hz) and AC (50 / 60 Hz)
   High frequency noise filter (75 / 100 / 150 / 200 Hz)
Calibration Test (1 mV):Frequency response and sensitivity test using internal 1 mV signal
Auto Power Switch off:After 5, 10, 15 minutes inactive operation
Power Requirements:AC : AC 100 – 240V + 10% ~ 50 / 60 Hz (Fully charged 2 hrs record)
   DC : Built – in rechargeable battery (NiMH, + 19,2V, 2200mAh)
A/D conversion:12 bits
Sampling rate:500 Hz (Input Unit : 8,000 Samples/s)
Input impedance:Greater than 100 MΏ
CMRR:Greater than 100 dB
Detection Parameter:Pace Maker Detection (Option) / Variable R-R Detection / Real Timeheart rate
Alarm:Paper empty / Lead-off/ Low Battery Level
Performance:AAMI Requirements
Safety:Class I (Degree of protection againts electric shock
   Defibrilation – proof type CF aplied parts
   IEC60601-1/IEC60601-2-25
Patient Leakage Current:Less than 10 μA
Digital interference Port:2 USB-RS232, Ethernet LAN, Wireless – Bluetooth (Option)
PC Connection:PC Data Management, PC Net S/W (Option)
   Stress ECG Interface, Stress ECG S/W (Option)
External Printer:USB Connection (Inkjet / Laser Printer)
Memory:Internal SD Card to save up to 2500 patient data (10 sec data)
   External USB memory stick
Display LCD:7″ Color, 800 x 480dots, Viewing area : 152. 40mm x 91.44 mm
Key Operation:Alphanumeric membrane hard key and touch screen
Dimension:332 x 308 x 103.8 mm
Weight:3.3 Kg Including battery
Temperature:Operating (10 – 40 ⁰C) Storage (-20 – 60 ⁰C)
Relative Humidity:Operating (10 – 80 %) Storage (-0 – 90 %)
Atmosphere pressure:50 – 106 kPa

[:]